-17% sale
16
16" Sealer Repair Kit For SMH400C $66.11

Each 16" Sealer Repair Kit for 16" Impulse Hand Sealer with Trimmer comes with 2 heating elements, 2 lower PTFE non stick strips, 1 blade and 1 upper PTFE non stick strip. It is always a smart idea to have more than one replacement heating wire and more then one lower PTFE non stick strip on hand so that production never misses a beat. 16 inch Sealer Service Kit for 16" Impulse Hand Operated Manual Sealer with built in Trimmer Please follow these instructions for replacing element wires and teflon covers and insulator strip. 1. Unplug unit. 2. Unscrew (2 philips head screws) and remove cutter bar. 3. Unscrew chrome side plate and remove teflon cover. This exposes element wire. 4. Unhook old wire from post. Remove insulator strip below wire. Replace adhesive strip cover all exposed metal. 5. Reattach new element wire, cover with new teflon, replace side plate and cutter bar. To Replace Cutting Blade 1. Slide cutter handle to cutout notch on upper arm and lift out. 2. Loosen (do not remove) screw and use pier to remove and install new blade. 3. Slide new blade in and tighten screw. Be careful of sharp blade. Reverse #1. CAUTION - USE EXTREME CARE TO INSURE PROPER ALIGNMENT OF ELEMENT WIRE AND INSULATOR STRIP. Weight: 0.1 lbs Qty/Each: 1

-17% sale
16
16" Sealer Service Kit For SMH400 $61.50

Each 16" Sealer Repair Kit for 16" Impulse Hand Sealer comes with 2 heating elements, 2 lower Teflon strips and 1 upper teflon strip. It is always a smart idea to have more than one replacement heating wire and more then one lower Teflon strip on hand so that production never misses a beat. Please follow these instructions for replacing element wires and teflon covers and insulator strip. 1. Unplug unit. 2. Unscrew (2 philips head screws) and remove cutter bar. 3. Unscrew chrome side plate and remove teflon cover. This exposes element wire. 4. Unhook old wire from post. Remove insulator strip below wire. Replace adhesive strip cover all exposed metal. 5. Reattach new element wire, cover with new teflon, replace side plate and cutter bar. Weight: 0.1 lbs Qty/Each: 1

-17% sale
12
12" Sealer Service Kit For SMH300C $57.90

Each 12" Sealer Repair Kit for 12" Impulse Hand Sealer with Trimmer comes with 2 heating elements, 2 lower Teflon strips, 1 blade and 1 upper Teflon strip. It is always a smart idea to have more than one replacement heating wire and more then one lower Teflon strip on hand so that production never misses a beat. Please follow these instructions for replacing element wires and teflon covers and insulator strip. 1. Unplug unit. 2. Unscrew (2 philips head screws) and remove cutter bar. 3. Unscrew chrome side plate and remove teflon cover. This exposes element wire. 4. Unhook old wire from post. Remove insulator strip below wire. Replace adhesive strip cover all exposed metal. 5. Reattach new element wire, cover with new teflon, replace side plate and cutter bar. To Replace Cutting Blade 1. Slide cutter handle to cutout notch on upper arm and lift out. 2. Loosen (do not remove) screw and use pier to remove and install new blade. 3. Slide new blade in and tighten screw. Be careful of sharp blade. Reverse #1. CAUTION - USE EXTREME CARE TO INSURE PROPER ALIGNMENT OF ELEMENT WIRE AND INSULATOR STRIP. Weight: 0.1 lbs Qty/Each: 1

-17% sale
12
12" Sealer Service Kit For SMH300 $54.22

Each 12" Sealer Repair Kit for 12" Impulse Hand Sealer comes with 2 heating elements, 2 lower Teflon strips and 1 upper teflon strip. It is always a smart idea to have more than one replacement heating wire and more then one lower Teflon strip on hand so that production never misses a beat. This 8 inch sealer with built in trimmer comes with an extra service kit, but we are always here to supply you with another one, if need be. Please follow these instructions for replacing element wires and teflon covers and insulator strip. 1. Unplug unit. 2. Unscrew (2 philips head screws) and remove cutter bar. 3. Unscrew chrome side plate and remove teflon cover. This exposes element wire. 4. Unhook old wire from post. Remove insulator strip below wire. Replace adhesive strip cover all exposed metal. 5. Reattach new element wire, cover with new teflon, replace side plate and cutter bar. Weight: 0.1 lbs Qty/Each: 1

-17% sale
8
8" Sealer Service Kit For SMH200C $48.70

Each 8 inch Sealer Repair Kit for 8" Impulse Hand Sealer with Trimmer comes with 2 heating elements, 2 lower teflon strips, 1 blade and 1 upper teflon strip. It is always a smart idea to have more than one replacement heating wire and more then one lower teflon strip on hand so that production never misses a beat. Please follow these instructions for replacing element wires and teflon covers and insulator strip. 1. Unplug unit. 2. Unscrew (2 philips head screws) and remove cutter bar. 3. Unscrew chrome side plate and remove teflon cover. This exposes element wire. 4. Unhook old wire from post. Remove insulator strip below wire. Replace adhesive strip cover all exposed metal. 5. Reattach new element wire, cover with new teflon, replace side plate and cutter bar. To Replace Cutting Blade 1. Slide cutter handle to cutout notch on upper arm and lift out. 2. Loosen (do not remove) screw and use pier to remove and install new blade. 3. Slide new blade in and tighten screw. Be careful of sharp blade. Reverse #1. CAUTION - USE EXTREME CARE TO INSURE PROPER ALIGNMENT OF ELEMENT WIRE AND INSULATOR STRIP. Weight: 0.1 lbs Qty/Each: 1

-17% sale
8
8" Sealer Service Kit For SMH200 $50.71

Each 8 inch Sealer Repair Kit for 8" Impulse Hand Sealer comes with 2 heating elements, 2 lower teflon strips and 1 upper teflon strip. It is always a smart idea to have more than one replacement heating wire and more then one lower teflon strip on hand so that production never misses a beat. Weight: 0.1 lbs Qty/Each: 1

-17% sale
4
4" Sealer Service Kit For SMH100 $36.89

Each 4" Sealer Repair Kit for 4" Impulse Hand Sealer comes with 2 heating elements and 2 Teflon strips. It is always a smart idea to have more than one replacement heating element wires and more then one Teflon strip on hand so that production never misses a beat. Please follow these instructions for replacing element wires and teflon covers and insulator strip. 1. Unplug unit. 2. Unscrew (2 philips head screws) and remove cutter bar. 3. Unscrew chrome side plate and remove teflon cover. This exposes element wire. 4. Unhook old wire from post. Remove insulator strip below wire. Replace adhesive strip cover all exposed metal. 5. Reattach new element wire, cover with new teflon, replace side plate and cutter bar. Weight: 0.1 lbs Qty/Each: 1

7

Was it awesome!

Please share your Shopping experience with us